ADSS Fiber Optical Cable Single Jacket 100M SPAN SM G652D - 96F
Product Description
ADSS Fiber Optical Cable Single Jacket 100M SPAN SM G652D - 96F | |||||||
Max Span: 100m MAT=3700N | |||||||
| |||||||
| |||||||
Characteristics | |||||||
Item | Description | ||||||
Fiber Optic | UV fiber G.652.D;@1310nm ≤0.35dB/km; | ||||||
Tube filling compound | Water Blocking & Moisture Proof Thyrotrophic gel | ||||||
Loose tube | Colors of tubes PBT | ||||||
Filler | PP Diameter same as tube | ||||||
Center strength member | GFRP Diameter same as tube | ||||||
Water blocking tape | 0.28mm thickness | ||||||
Binder | 2 wires Polyester Yarns Cable core binding | ||||||
Ripcords | 2 wires | ||||||
Dielectric Strength Members | Aramid Yarns | ||||||
Outer Jacket | 1.6-2.0mm thickness HDPE | ||||||
Cable Out Diameter | 14.0±1.0mm(Design according to customer requirements) | ||||||
Cable Weight | 125±15kg(Design according to customer requirements) | ||||||
Length Cable/Spool | 4km (2% tolerance in more) | ||||||
Temperature range | -20~+65℃ | ||||||
Standards | |||||||
ITU-T Rec. G.652.D | IEC 60794 | GR-409 | |||||
IEEE1222-2004 | ICEA-596 | YD/T 1997-2009 | |||||
Colors -12 Chromatography | |||||||
No. | 1 | 2 | 3 | 4 | 5 | 6 | |
Color | Blue | Orange | Green | Brown | Gray | White | |
No. | 7 | 8 | 9 | 10 | 11 | 12 | |
Color | Red | Black | Yellow | Violet | Pink | Aqua |
ADSS Singal Jacket
ADSS | |||||||||||||||||||
ADSS Single sheath | |||||||||||||||||||
All Dielectric Self-supporting Aerial Cable | |||||||||||||||||||
| |||||||||||||||||||
Structure Description | |||||||||||||||||||
1. Loose Tube: Thermoplastic material,containing optical fibres and filled with gel. | |||||||||||||||||||
2. Filler Elements: Thermoplastic rods. | |||||||||||||||||||
3.Central Strength Member(CSM):Glass fibre reinforced plasticrod (GFRP), | |||||||||||||||||||
4. Longitudinal Water Blocking Material:Water blocking tape. | |||||||||||||||||||
5. Peripheral Strength Member: Aramid yarn. | |||||||||||||||||||
6. Ripcord | |||||||||||||||||||
7. Outer Sheath: Black polyethylene. | |||||||||||||||||||
Features and Applications | |||||||||||||||||||
√ High tensile strength | |||||||||||||||||||
√ All dielectric structure and semi-dry core design | |||||||||||||||||||
√ Small diameter and light weight | |||||||||||||||||||
√ Self-supporting aerial installation | |||||||||||||||||||
Optical Characteristics | |||||||||||||||||||
G.652.D | G.655 | 50/125um | 62.5/125um | ||||||||||||||||
Attenuation | @850nm | - | - | ≤3.0 dB/km | ≤3.0 dB/km | ||||||||||||||
@1300nm | - | - | ≤1.0 dB/km | ≤1.0 dB/km | |||||||||||||||
@1310nm | ≤0.36 dB/km | ≤0.40 dB/km | - | - | |||||||||||||||
@1550nm | ≤0.22 dB/km | ≤0.23 dB/km | - | - | |||||||||||||||
Bandwidth | @850nm | - | - | ≥500 MHz · km | ≥200 MHz · km | ||||||||||||||
@1300nm | - | - | ≥1000 MHz · km | ≥600 MHz · km | |||||||||||||||
Polarization mode | Individual fiber | ≤0.20 ps/√km | ≤0.20 ps/√km | - | - | ||||||||||||||
Design link value (M=20,Q=0.01%) | ≤0.10 ps/√km | ≤0.10 ps/√km | - | - | |||||||||||||||
Technical Data | |||||||||||||||||||
Item | Contents | Fibers | |||||||||||||||||
Fibre Count | 6|12|24 | 48 | 72 | 96 | 144 | 288 | |||||||||||||
Loose Tube | Tubes* Fbres/Tube | 1x6 | 2x6 | 6x 8 | 6x12 | 8x12 | 12x12 | 24x12 | ||||||||||||
Outer diameter (mm) | 1.8 | 2.0 | 2.5 | 2.5 | 2.5 | 2.5 | |||||||||||||
Adjustable (OEM) | 1.5|2.0 | 1.8|2.3 | 2.1|2.3 | 2.1|2.3 | 2.1|2.3 | 2.1|2.3 | |||||||||||||
Central strength member | Material | Glass Fbre Reinforced Plasticrod (GFRP) | |||||||||||||||||
Diameter (mm) | 2.0 | 2.0 | 2.5 | 2.8 | 3.7 | 2.6 | |||||||||||||
Adjustable (OEM) | 1.8|2.3 | 1.8|2.3 | 2.5 | 2.8 | 3.7 | 2.6 | |||||||||||||
PE coated diameter (mm) | No | 4.2 | 7.4 | 4.8 | |||||||||||||||
Water Blocking | Material | Water blocking tape | |||||||||||||||||
Peripheral Strength | Material | Aramid Yarn | |||||||||||||||||
Outer Sheath | Thickness (mm) | 1.8mm(1.5-2.0mm OEM) HDPE | |||||||||||||||||
Cable diameter(mm) Approx. | 9.5 | 9.5|10 | 12.2 | 13.9 | 17.1 | 20.2 | |||||||||||||
Cable diameter(mm) Adjustable (OEM) | 8.0|8.5|9.0 | 10.5|11.0 | |||||||||||||||||
Operating temperature range(℃) | From -40~+70 | ||||||||||||||||||
Max. span (m) | 80m | 100m | 120m | 200m | 250m | ||||||||||||||||||
Climate condition | No Ice,25m/s Max Wind Speed | ||||||||||||||||||
MAT | Design according to customer requirements | ||||||||||||||||||
√ Other structure and fibre count are also available according to customer requirements. | |||||||||||||||||||
√ Cable diameter and weight in this table is typical value, which will fluctuate according to different designs | |||||||||||||||||||
√ The span needs to be recalculated due to other climate conditions according to the installation area. |
Fiber Datas-SM
Fiber Optical Test Datas | ||||||||
The properties of single mode optical fiber (ITU-T Rec. G652|G657) | ||||||||
Category | Description | G.652.D | G.652.D | G.652.D | G.657.A1 | G.657.A2 | Unit/单位 | |
Transmission | Attenuation Coefficient | @1310 nm | ≤0.35 | ≤0.34 | ≤0.32 | ≤0.34 | ≤0.34 | dB/km |
@1285-1330 nm | ≤0.37 | ≤0.35 | ≤0.37 | ≤0.37 | dB/km | |||
@1383 nm(after hydrogen aging)氢老化后 | ≤0.30 | ≤0.30 | ≤0.29 | ≤0.31 | ≤0.31 | dB/km | ||
@1490 nm | ≤0.24 | ≤0.22 | ≤0.23 | ≤0.23 | dB/km | |||
@1550 nm | ≤0.22 | ≤0.21 | ≤0.18 | ≤0.2 | ≤0.2 | dB/km | ||
@1525-1575 nm | ≤0.22 | ≤0.19 | ≤0.21 | ≤0.21 | dB/km | |||
@1625 nm | ≤0.25 | ≤0.24 | ≤0.2 | ≤0.22 | ≤0.22 | dB/km | ||
Mode Field Diameter | @1310 nm | 8.6±0.4 | 9.0±0.4 | 9.0±0.3 | 9.0±0.3 | 8.6±0.4 | µm | |
@1550 nm | 9.8±0.5 | 10.2±0.4 | 10.2±0.4 | 10.2±0.4 | 9.6±0.5 | µm | ||
Cable Cut-off wavelength(λ cc) | ≤1260 | ≤1260 | ≤1260 | ≤1260 | ≤1260 | nm | ||
Zero Dispersion Wavelength | 1300-1324 | 1300-1324 | 1300-1324 | 1300-1324 | 1300-1324 | nm | ||
Zero Dispersion Slope | ≤0.092 | ≤0.092 | ≤0.09 | ≤0.09 | ≤0.09 | ps/nm²/km | ||
Dispersion Coefficient | @1285-1339 nm | ≤3.4 | ≤3.2 | ≤3 | ≤3.4 | ps/(nm·km) | ||
@1271-1360 nm | ≤5.3 | ps/(nm·km) | ||||||
@1550 nm | ≤ 18 | ≤ 18 | ≤ 17 | ≤ 17 | ≤ 18 | ps/(nm·km) | ||
@1625 nm | ≤ 22 | ≤ 22 | ≤ 21 | ≤ 21 | ≤ 22 | ps/(nm·km) | ||
PMD Maximum Individual Fiber | ≤0.1 | ≤0.1 | ≤0.1 | ≤0.1 | ≤0.1 | ps√km | ||
PMD Link Design Value | ≤0.06 | ≤0.06 | ≤0.06 | ≤0.06 | ≤0.06 | ps/√km | ||
Point Discontinuity | @1310 nm, @1550 nm | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.05 | dB | |
EGRI | @1310 nm | 1.4671 | 1.4671 | 1.4671 | 1.4676 | |||
@1550 nm | 1.4675 | 1.4675 | 1.4675 | 1.4683 | ||||
@1625 nm | 1.468 | 1.468 | 1.468 | 1.4685 | ||||
Macro Bending Loss | 10turns of 15mm radius | ≤0.25 | ≤0.03 | @1550 nm | ||||
1turns of 10mm radius | ≤0.75 | ≤0.1 | ||||||
1turns of 7.5mm radius | ≤0.2 | |||||||
1turns of 5mm radius | ||||||||
100turns of 30mm radius | ≤0.05 | ≤0.05 | ≤0.05 | @1625 nm | ||||
10turns of 15mm radius | ≤1.0 | ≤0.1 | ||||||
1turns of 10mm radius | ≤1.5 | ≤0.2 | ||||||
1turns of 7.5mm radius | ≤0.5 | |||||||
1turns of 5mm radius | ||||||||
Fiber Optical Test Datas | ||||||||
The properties of single mode optical fiber (ITU-T Rec. G652|G657) | ||||||||
Category | Description | G.652.D | G.652.D | G.652.D | G.657.A1 | G.657.A2 | Unit/单位 | |
Dimensions | Cladding Diameter | 125±0.7 | 125±0.5 | 125±0.5 | 125±0.5 | 125±0.5 | µm | |
Core / Cladding Concentricity Error | ≤0.5 | ≤0.4 | ≤0.4 | ≤0.4 | ≤0.4 | µm | ||
Cladding Non-circularity | ≤1.0 | ≤0.7 | ≤0.6 | ≤0.7 | ≤0.7 | % | ||
Coating Diameter | 245±5 | 245±5 | 245±5 | 242±5 | 242±5 | µm | ||
Coating / Cladding Concentricity Error涂覆层/包层同心度误差 | ≤12 | ≤12 | ≤8 | ≤8 | ≤8 | µm | ||
Mechanical Characteristics | Proof Test | Fiber Strain | ≥1 | ≥1 | ≥1 | ≥1 | ≥1 | % |
Fiber Load | ≥9 | ≥9 | ≥9 | ≥9 | ≥9 | N | ||
Stress | ≥100 | ≥100 | ≥100 | ≥100 | ≥100 | kpsi | ||
Dynamic Stress Corrosion Susceptibility Factor | Unaged &Aged(30 days@85℃,85%R.H.) | ≥20 | ≥20 | ≥20 | ≥20 | ≥20 | ||
Coating Strip Force | Peak Value | 1.3-8.9 | 1.3-8.9 | 1.3-8.9 | 1.3-8.9 | 1.3-8.9 | N | |
Fiber Curl | ≥4 | ≥4 | ≥4 | ≥4 | ≥4 | m | ||
Environmental Characteristics | Dry heat aging干热(30days@85℃) | @1310 nm, @1550 nm | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.05 | dB/km |
Accelerated ageing 湿热(30days@85℃,85%R.H.) | @1310 nm, @1550 nm | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.05 | dB/km | |
Temperature Cycling温度循环 | @1310 nm, @1550 nm | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.05 | dB/km | |
Water Soak浸水(30days@23℃) | @1310 nm, @1550 nm | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.05 | dB/km |
Main TEST for Mechanical & Environmental Characteristics | |||
NO | ITEM | TEST METHOD | ACCEPTANCE REQUIREMENTS |
1 | Tensile Strength IEC 794-1-E1 | - Load:5000 N | - Loss change 0.1 dB |
2 | Crush Test | - Load: 3000 N/100mm | - Loss change 0.1 dB |
3 | Impact Test | - Points of impact: 5 | - Loss change 0.1 dB |
4 | Repeated Bending IEC 60794-1-E6 | - Bending Dia.: 20 x OD | - Loss change 0.1 dB |
5 | Torsion | - Length: 1m | - Loss change 0.1 dB |
6 | Water Penetration IEC 60794-1-F5B | - Height of water: 1m | - No water shall have leaked from the opposite end of cable |
7 | Temperature Cycling IEC 60794-1-F1 | - Temperature step: | - Loss change 0.1 dB |
8 | Compound Flow IEC 60794-1-E14 | - Sample length: 30 cm | - No compound flow |
9 | Sheath High Voltage Test | - On line test | - No sheath breakdown |
Cable Marking&Fibers Colors | ||||||||
Sheath marking | ||||||||
COMPANY Fiber cable name N*cores G.652D 2019 XXXXm | ||||||||
COMPANY | Manufacturer’s brand | |||||||
2022 | Manufacture year | |||||||
Fiber cable name | Cable type | |||||||
G.652D | N cores single-mode optical fiber (ITU-T Rec. G.652D) | |||||||
XXXXm | Mark of meters | |||||||
*The marking is printed every 1 meter; | ||||||||
Also can according to client cable marking. | ||||||||
1 The color of marking is white, 2 An occasional unclear of length marking is permitted if both of the neighboring markings are clear. 3 The both cable ends are sealed with heat shrinkable end caps to prevent water ingress. | ||||||||
Fiber color and Binder color code: according to EIA/TIA 598B | ||||||||
No. | 1 | 2 | 3 | 4 | 5 | 6 | ||
Color | Blue | Orange | Green | Brown | Gray | White | ||
No. | 7 | 8 | 9 | 10 | 11 | 12 | ||
Color | Red | Black | Yellow | Violet | Pink | Aqua |
OEM Structure Technical Data
Structure Technical Data(OEM) | ||||||||
No. of cable | / | 12 | 24 | 48 | 96 | 120 | 144 | |
Design | / | 3+2+1 | 1+4+1 | 1+4+1 | ||||
Fiber type | / | G.652.D | ||||||
Central Strength Member | Material | mm | FRP | Steel Wire | |||||
Diameter | 1.2mm | 1.0 mm | |||||||
Other Strength Member | Material | mm | ||||||
Diameter | ||||||||
Loose Tube | Material | mm | PBT | |||||
Diameter | 2.1mm | 1.8mm | |||||||
Thickness | 0.35mm | |||||||
MAX.NO./per | 12 | 24 | |||||||
Filler | Material | mm | PP | |||||
Diameter | 1.8mm | |||||||
No. | ||||||||
Water Blocking Layer(Material) | / | Water Blocking Yarn& Water Blocking tape | ||||||
Yarn Strength Member | / | Aramid Yarn | ||||||
Outer Sheath | Material | mm | HDPE | |||||
Thickness | 0.8mm | 1.6mm | 1.9mm | |||||
Color | Black | |||||||
Cable Diameter(±0.2mm) | mm | 9.0mm | 13.0mm | |||||
Cable Wetght(±10.0kg/km) | kg/km | 75 | 95 | |||||
Max. Installation Tension | N | 2400 | ||||||
Min.bending radius | Without Tension | mm | 10.0×Cable-φ | |||||
Under Maximum Tension | mm | 20.0×Cable-φ | ||||||
Temperature | Installation | ℃ | -20~+60 | |||||
Transport&Storage | -40~+70 | |||||||
Operation | -40~+70 |
Packing
Packing and Marking |
1. Packing |
1.1 Each single length of cable shall be reeled on Wooden Drum suitable for long distance shipment. |
1.2 Covered by plastic buffer sheet. |
1.3 Sealed by strong wooden battens. |
1.4 At least 1 m of inside end of cable will be reserved for testing. |
1.5 Drum length |
1.5.1 Standard drum length is 2000-4000m |
1.5.2 Single length not less than 96% of standard length per drum shall be permitted for quantity not exceeding 10% of the total supply; |
1.5.3 Total quantity is at least the ordered quantity. |
2. Drum Marking |
2.1 Cable drum |
- Manufacturer brand; |
- Roll-direction arrow; |
- Cable outer end position indicating arrow; |
- The word “FIBER OPTICAL CABLE”; |
- Origin, The word “MADE IN CHINA”; |
- Caution plate indicating the correct method for loading, unloading and convey the cable; |
- Other customer information such as contract no., project no., and delivery destination. (if needed) |
2.2 Marking plate |
- Product name; |
- Cable type and size; |
- Drum length; |
- Gross / Net weight in kilograms; |
- Drum number in meters; |
- Manufacturer's name; |
- Manufacturing year and month; |
- Project number, contract number or purchasing order number (if needed). |