NO.7101106 1/2" RF

Specification

1/2" RF Coaxial Cable  NO.7101106


Construction Parameters:

Inner Conductor

4.80±0.05mm Copper Clad Aluminum Wire

Insulation

12.00±0.20mm Foamed PE           

Outer Conductor

13.80±0.15mm Annular Corrugated Copper Tube

Jacket

15.70±0.20mm PE, Black

Jacket Thickness

0.80mm



Electrical Characteristics:

Capacitance

76 pF/m

Impedance

50 ±2 Ω

Velocity of Propagation

87%

Peak Power Rating

40 KW

Max. Operating Frequency

8.8 GHz

Insulation Resistantce

>10000 MΩ.km

DC Breakdown Voltage

6000 V

Jacket Spark Test Voltage

8000 Vrms

Inner Conductor DC Resistance

1.62  Ω/km

Outer Conductor DC Resistance

4.30  Ω/km

Shielding Attenuation

≥120dB

VSWR


800MHz-1000MHz

≤ 1.13

1700MHz-2700MHz

≤ 1.15

2700MHz-4000MHz

≤ 1.20

4000MHz -5000MHz

≤ 1.20




PIM





Intermodulation (3rd order,2*20W)

≤ - 160 dBc































Mechanical Properties:

Bending Radius (Single Bend)

55 mm

Bending Radius (Repeated Bend)

130 mm

Bending moment

6.5 Nm

Flat plate crush strength

8 N/mm

Tensile Strength

950 N










Mechanical Properties:


PE Jacket

LSZH Jacket

Installation Temperature

-40℃ to +60 ℃

-20℃ to+60 ℃

Operating Temperature

-55℃ to +85 ℃

-30℃ to +80 ℃

Storage Temperature

-70℃ to +85 ℃

-30℃ to +80 ℃




Attenuation(20℃):

Frequency (MHZ)

Attenuation (dB/100m)

Average Power (KW)

200

3.18

2.41

450

4.88

1.57

800

6.64

1.16

900

7.08

1.09

1800

10.35

0.75

2000

10.98

0.70

2200

11.58

0.67

2500

12.44

0.62

2700

13.02

0.59

3000

13.80

0.56

3500

15.15

0.51

4000

16.40

0.47

5000

18.62

0.42

6000

20.70

0.37




Maximum attenuation value shall be 105% of the nominal attenuation value










Standards and Order Informations:

Fire Resistant

IEC 60754-1,-2; IEC 60332-1,-2; IEC 61034-1,-2; IEC 60332-3-24

RoHS

Compliant RoHS 2011/65/EU

Delivery time

Normally 25 days after received the deposit.

Marking

HELLOSIGNAL 1/2" RF COAXIAL CABLE ××× M


NO.7101107 1/2" AL RF