Twin And Earth Cable

Product Description


Twin And Earth Cable


Application:



Cable Standards:

This cable has a bare protective conductor
plus 1, 2 or 3 cores.
Used for fixed installations in dry or
damp premises clipped direct to surface,
on trays or in free air.
Where mechanical protection is required,
it can be laid in conduit or trunking.



BSEN 50363-3, BS 6004



Flame Retardant according to IEC/EN 60332-1-2









































Product Description:

Conductor

RE: 1mm⊃2; to 2.5mm⊃2;: Class 1 solid copper

RM: 4mm⊃2; to 16mm⊃2;: Class 2 stranded copper

Circuit Protection
Conductor (Earth)

1mm⊃2; to 2.5mm⊃2;: Class 1 solid copper

4mm⊃2; to 16mm⊃2;: Class 2 stranded copper

Insulation

Polyvinyl Chloride (PVC)

Sheath

Polyvinyl Chloride (PVC)


Characteristics:

Voltage Rating Uo/U

300/500V

Temperature Rating

-5°C to +70°C

Minimum Bending Radius

Fixed: 6 x overall diameter


Core Identification:



























1 Core:


Brown











































2 Core:


Brown



Blue








































2 Core:


Brown



Blue








































3 Core:


Brown



Blue



Black






































      Should not be installed at temperatures below 0°C or above +60°C




































































































































Dimensions:

Zion Code

No. Of
Cores

Nominal Cross Sectional Area(mm⊃2;)

Nominal Thickness
Of Insulation
(mm)

Nominal overall
diameter
(mm)

Nominal overall
diameter
(mm)

Nominal overall
diameter
(mm)

Nominal overall
diameter
(mm)

Nominal
Weight
Kg/km

TAEC2x1.0

2

1

1

1

0.6

0.9

4.35 x 7.95

68

TAEC2x1.5

2

1.5

1

1

0.7

0.9

4.85 x 8.90

87

TAEC2x2.5

2

2.5

1

1.5

0.8

1

5.65 x 10.65

120

TAEC2x4.0

2

4

2

1.5

0.8

1

6.30x 11.95

172

TAEC2x6.0

2

6

2

2.5

0.8

1.1

7.10x 13.70

235

TAEC2x10

2

10

2

4*

1

1.2

8.70x 17.25

373

TAEC2x16

2

16

2

6*

1

1.3

9.85 x 20.0

530

TAEC3x1.0

3

1

1

1

0,6

0.9

4.35 x 9.80

91

TAEC3x1.5

3

1.5

1

1

0.7

0.9

4.85 x 11.2

115



























Conductors:


Nominal Cross Sectional Area
(mm⊃2;)

MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC
ohms/km




Plain Wires




1

18.1




1.5

12.1




2.5

7.41





























Class 2 Stranded Conductors for Single Core and Multi-Core Cables


Nominal Cross Sectional Area  (mm⊃2;)

Current Carrying Capacity Amps

MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC
ohms/km


Annealed Copper Conductor


Circular

Plain Wires


4

7

4.61



6

7

3.08



10

7

1.83



16

7

1.15


        The above table is in accordance with EN 60228




























H03VVH2-F Flexible Power Cable

H05VV-F Flexible Cable

H03VV-F Flexible Cable

H05V-K / H07V-K Flexible Cable

CYKYlo Installation Multi-Core Cables