16mm²-B (PV1-F / H1Z2Z2-K) Single core Solar Cable

Product Description

16mm⊃2;-B (PV1-F / H1Z2Z2-K)
NO.7194005

General characteristics:

 

Appllcation:

Specifically designed to connect photovoltaic system components inside and outside buildings
and facilities under high mechanical demands and extreme weather conditions.

Cable Construction:

Conductor



 

Metarial

Tinned annealed copper

Area(mm⊃2;) :

1*16

Construction(N/mm) :

128/0.40

Conductor(Dia./mm) :

5.25


 

Insulation

120℃ XLPE

Standard thickness (mm) :

0.9

Standard diameter (mm) :

7.05±0.1

Jacket

120℃ XLPE, Black

Standard thickness (mm) :

1.2

Outer diameter (mm) :

9.45±0.2

Making

ZION COMMUNICATION PV1-F / H1Z2Z2-K 1x16mm⊃2; UV Res
DC 1.0KV AC 0.6/1.0KV (DC 1.5KV AC 1.0/1.0KV)
SOLAR CABLE








Package

BOX  (art.code ZC-100-16mm/ZC-500-16mm)     


 


PALLET     

Size:     

Amount of boxes on one pallet:


Weight of total pallet:


Cable length pallet:



Electrical properties

Nominal Voltage:

PV1-F:          DC 1.0KV   AC 0.6/1.0KV
H1Z2Z2-K:   DC 1.5KV   AC 1.0/1.0KV

Ambient Temperature:

-40℃~+90℃

Max.Temperature at conductor:

+120℃

Service life:

25 years ( -40~+90℃)

Conductor resistance (20℃):

1.24Ω/km

Insulation resistance (70℃):

≥1000 MΩ/km

Withstand voltage(V/5min)

AC6500

Speak voltage(V/5min)

AC6500

Min bending radius(mm)

5*D


Main performance parameter of finished cable

Voltage test of finished cable

Min.time of dipping in water

≥1(h)

Testing voltage (AC)

6500(V)

Min.voltage applying time at one time

5(min)

Test result

no breakdown

Sheated surface resistance

Length of specimen:

250mm

Test result

≥109Ω

Penetrate the insulation resistance

Temperature

20℃

Test result

≥1014Ω

High temperature stress

Temperature

140℃

A: with 1.2 Voltage test

A: No breakdown

B: deep pressure

B: Wall thickness 50%

Damp-heat test

Temperature

90℃

Humidity

85%

Aging before and after the tenslle strength of Change

≤30%

Aging before and after the elongation at break of Change

≤-30%


Acid-alkali Resistance

Min.time of dipping in

168h

Aging before and after the tensile strength of Change

≤-30%

Elongation

≥100

Low-temperature bending

Temperature

-40℃

Time

16h

Test result

No crack

Ozone resistance

Ozeone concentration %

200±50x10-6

Time

72h

Test result

No crack

Heat schrinkable jacket test

Test result

≤2%

Flame retardant-Vertical burn


Flxture on the lower edge from the starting point and carbonization

≥50mm

Burning fuel downward from the lower edge of bottom fixture

≤540mm

Halogen content of non-metallic materials

Test result


Chlorine and bromine content

HCL≤0.5HBr≤0.5%

Fluoride content

F≤0.1%

The inner layer of insulation and sheath of the mechanical properties

Test result


Aging before tensile strength

8.0N/mm⊃2;

Aging before elongation

125%

Aging before and after the tensile strength of change

-30%

Aging before and after the elongation at break of change

-30%

Hot extension

Temperature

200℃

Test result-The inner layer of insulation and sheath


Elongation under load

≤100%

Elongation after unloading

≤25%










25mm²-B (PV1-F / H1Z2Z2-K) Single core Solar Cable

10.0mm²-Black/Red (H1Z2Z2-K) Single core Solar (PV) Cable (NO.7194004)- IEC 62930 / EN 50618:2014

6.0mm²-Black/Red (H1Z2Z2-K) Single core Solar (PV) Cable (NO.7194003)- IEC 62930 / EN 50618:2014

4.0mm²-Black/Red (H1Z2Z2-K) Solar (PV) Cable (NO.7194002)- IEC62930/EN50618:2014

2.5mm²-B (PV1-F / H1Z2Z2-K) Single core Solar Cable