6.0mm²-Black/Red (H1Z2Z2-K) Single core Solar (PV) Cable (NO.7194003)- IEC 62930 / EN 50618:2014

  • Solar cable

  • hellosignal

  • NO.7194003

  • Power Cables

  • Normally 25 working days

  • NINGBO, SHANGHAI

Availability:

6.0mm²-Black/Red (H1Z2Z2-K)
(NO.7194003)- IEC 62930 / EN 50618:2014


 General characteristics:

General characteristics


 Application:

Specifically designed to connect photovoltaic system components inside and outside buildings

and facilities under high mechanical demands and extreme weather conditions.



 Cable Construction:

Cable Construction


Conductor

Material: Tinned annealed copper

Area(mm²): 1*6.0

Construction(N/mm): 84/0.285±0.005

Stranded diameter(mm): 3.016Ref.)

 

Insulation: 125℃ XLPE Black

Nom. thickness (mm): 0.8 (Ref.)

Standard diameter (mm): 4.6±0.1

 

Jacket: 125℃ XLPE, Black / Red

Min. thickness (mm): 0.7

Nom. thickness (mm): 0.8 (Ref.)

Outer diameter (mm): 6.2±0.1

Making: ZION COMMUNICATION TÜV  SÜD  IEC62930  

EN50618: 2014 H1Z2Z2-K 1×6.0mm² -40℃ to+90℃   

DC 1500V HALOGEN FREE LOW SMOKE



 Package:

100M/Roll, 500M/Wooden Drum



 Electrical properties:

Nominal Voltage: H1Z2Z2-K: DC 1.5KV AC 1.0/1.0KV

Ambient Temperature: -40℃~+90℃

Max.Temperature at conductor: +125℃

Service life: 25 years ( -40℃~+90℃)

Voltage: 600/1000V

Temperature: -40~90℃

Conductor resistance (20℃): 3.39Ω/km

Insulation resistance (70℃): ≥1000 MΩ/km

Withstand voltage(V/5min): AC6500

Speak voltage(V/5min): AC6500

Min bending radius(mm): 4*D


 The main performance parameter of finished cable:

  • Performance of Finished Cable

Voltage Test:

Min. Dipping Time in Water: ≥1 hour

Testing Voltage (AC): 6500V

Min. Voltage Applying Time: 5 min

Test Result: No breakdown

Sheath Surface Resistance:

Length of Specimen: 250mm

Test Result: ≥10⁹Ω

Insulation Resistance at 20℃:

Test Result: ≥10¹⁴Ω

High Temperature Stress (140℃):

Voltage Test (1.2V): No breakdown

Deep Pressure: Wall thickness reduced by 50%

Damp-Heat Resistance (90℃, 85% Humidity):

Tensile Strength Change: ≤30%

Elongation at Break Change: ≤-30%


  • Chemical & Mechanical Resistance

Acid-Alkali Resistance:

Dipping Time: 168 hours

Tensile Strength Change: ≤-30%

Elongation: ≥100%

Low-Temperature Bending (-40℃, 16h):

Test Result: No crack

Ozone Resistance:

Ozone Concentration: (200±50)×10⁻⁶

Test Time: 72 hours

Test Result: No crack

Heat Shrinkable Jacket Test:

Test Result: ≤2% Shrinkage


  • Flame Retardancy & Halogen Content

Flame Retardant – Vertical Burn Test:

Carbonization Length: ≥50mm

Downward Flame Spread: ≤540mm

Halogen Content (Non-Metallic Materials):

Chlorine & Bromine (HCl / HBr): ≤0.5%

Fluoride (F): ≤0.1%


  • Mechanical Properties of Insulation & Sheath

Before Aging:

Tensile Strength: 8.0 N/mm²

Elongation: 125%

After Aging:

Tensile Strength Change: ≤-30%

Elongation at Break Change: ≤-30%

Hot Extension (200℃):

Elongation Under Load: ≤100%

Elongation After Unloading: ≤25%



Previous: 
Next: 
We use cookies to enable all functionalities for the best performance during your visit and to improve our services by giving us some insight into how the website is being used. Continued use of our website without changing your browser settings confirms your acceptance of these cookies. For details, please see our privacy policy.
×