Through the laying of Ethernet wires outside, the connection of security cameras, access points, smart lighting, and remote buildings is achieved. However, in outdoors settings, ingress from sun, rain, and temperature fluctuations make it harder to have long-lasting cabling systems. Regarding the additional components, your network could fail in months rather than years.
This guide gives a detailed explanation of the important elements in efficient outdoor Ethernet installations. We will deal with and go into technical standards, real-world deployment solutions, and economical solutions widely — so you will be ready to put together a trustworthy network that enjoys a long lifespan.
Contrary to this, Ethernet cables are not specifically made for outside applications.
Use: For the outside application, select Cat 6 or Cat 6a with UV protection and water resistance jacket.
Regular indoor cables should be avoided; they will quickly deteriorate due to sun rays and other environmental factors.
Jacket Material: Get the LSZH (low smoke zero halogen) or PVC with UV inhibitors.
Shielding: Use S/FTP shielding from the electric lines or motors that contribute to the EMI.
Temperature Range: Outside cables work efficiently at -40 °C to +70 °C (-40 °F to 158 °F).
Water Blocking: While some cables embrace either a gel-filled core or a dry tape to prevent moisture intrusion.
Even with outdoor-rated cable, conduit is a best practice — especially for buried or exposed runs.
Type | Use Case | Pros | Cons |
---|---|---|---|
PVC Schedule 40 | Buried runs, above-ground | UV-resistant, low cost | Can become brittle in extreme cold |
PVC Schedule 80 | High-impact areas (e.g., driveways) | Thicker walls, more durable | Harder to bend |
EMT Metal Conduit | Exposed walls, industrial sites | Crush-resistant, EMI shielding | Must be grounded, can corrode |
Installation Tip: Always slope conduit slightly downward away from buildings to prevent water pooling. Use expansion joints in runs over 100 feet to handle thermal expansion.
If there is no other way, the splicing of cables outdoors should never be done with electrical tape or zip ties.
As a substitute, these IP68-rated waterproof enclosures with gel seals are very appropriate.
IP68 Rating: It is dust-tight and can be submerged to a depth of 1.5 meters, duration 30 minutes.
Gels: Secure around cables where they enter and block moisture from penetrability.
Mounting Options: This can be done either with the wall mounting, pole mounting, or directly beneath it.
These boxes keep the splices from water, rodents, and vibration (which is the main source of failure) — in fact, it is the most common aspect of long wiring runs.
Outdoor cables act as antennas for electrical surges — especially during storms.
Always install Ethernet surge protectors at both ends of a run, where the cable enters a building.
Clamping Voltage: Look for <10V for sensitive devices like PoE cameras.
Response Time: Should be <1 nanosecond.
Grounding: Must connect to a proper earth ground (≤5 ohms resistance).
Use PoE-compatible models if powering devices like access points or PTZ cameras.
Cables hanging between poles or buildings stretch over time.
Use:
Stainless steel cable hangers (UV and rust-resistant)
Tensioning kits with spring-loaded grips
Drip loops before entry points to shed water
Avoid tying cables with nylon zip ties — they cut into jackets over time. Use hook-and-loop straps or rubber-lined clamps instead.
After installation, test everything.
Essential Tools:
Cable certifier (e.g., Fluke DSX-5000) for verifying Cat 6 performance
Toner and probe for tracing cables in walls or conduit
Ping and throughput tester to confirm real-world speed
Even a $200 camera can go offline if the cable has a high crosstalk or impedance issue.
Q1: Can I use indoor Ethernet cable outdoors if it’s inside conduit?
A: Technically yes — but not recommended. If the conduit cracks or floods, moisture will destroy indoor cable fast. Always use outdoor-rated cable, even in conduit.
Q2: How deep should I bury Ethernet cable?
A: In conduit, bury at least 18 inches deep (NEC Article 300.5). Use warning tape 6 inches above the conduit. For direct burial cable (rare), follow manufacturer specs — usually 24 inches.
Q3: Do I need to ground the shield on shielded Ethernet cable?
A: Yes — but only at one end (usually the switch side) to avoid ground loops. Use a grounding block or patch panel with earth connection.
Q4: Can I run Ethernet and power in the same conduit?
A: Only if both are separated by a barrier or use isolated conduits. Otherwise, EMI can disrupt data. Never run low-voltage and AC power in the same conduit without separation.
Q5: What’s the maximum distance for outdoor Ethernet?
A: Same as indoors — 100 meters (328 feet) for reliable 1 Gbps. Beyond that, use fiber or a media converter. PoE also drops voltage over long runs — test power delivery at the device end.
Q6: Are waterproof RJ45 connectors reliable?
A: IP67 or IP68-rated keystone jacks work well for exposed ends. But they’re only as good as the installation. Always use strain relief and drip loops. Avoid field-terminated plugs — pre-made ones are more consistent.
Item | Low-Cost Risk | Smart Investment |
---|---|---|
Cable | Indoor Cat 5e | Outdoor Cat 6a, shielded |
Conduit | None or thin PVC | Schedule 80 or EMT |
Surge Protection | Skipped | UL-listed, grounded protector |
Enclosures | Zip-locked bags | Gel-sealed IP68 box |
Bottom Line: Spending 20% more upfront can reduce maintenance costs by 70% over 5 years.
Use outdoor-rated, shielded Cat 6 or Cat 6a
Run cable in UV-resistant conduit (buried or exposed)
Install surge protectors at building entry points
Seal splices in IP68 enclosures with drip loops
Support cable every 3–4 feet; avoid tension
Test with a cable certifier before going live
Outdoor Ethernet isn’t just about the cable — it’s about the full ecosystem of protection. UV rays, water, surges, and physical stress will find weak points. By using the right accessories, you build a network that survives the elements and avoids costly downtime.
Choose quality. Follow standards. Test thoroughly.
Your network’s durability starts with what’s outside the wall.
Contact us for more information
Will is the Copper Cabling Product Manager at Zion Communication,
specializing in the development and marketing of Ethernet cabling solutions.
With extensive industry experience, he is dedicated to delivering high-performance
and reliable cabling products to OEM/ODM clients worldwide.
will@zion-communication.com
+86 -18268007201