FR331-OS
Zion communication
Fire Cable
UL, ETL, CE,CPR, RoHS
100m,500m,500ft,1000ft
roll, wooden spool, carton, pallet
10KM
Normally 15 working days
NINGBO, SHANGHAI
T/T, L/C at sight, D/P at sight
| Availability: | |
|---|---|
Fire Resistant Cable 2 × 2.5 sq mm | IEC 60331-21 (FE90) / LSZH / BS 6387 Compliant (Red RAL 3000)

| Item | Specification |
|---|---|
| Product Name | Fire Resistant Cable |
| Model No. | FR331-0S-0225 |
| Construction Type | CU / FR / OS / LSZH (Overall Screened) |
| Conductor Material | Stranded Bare Copper (Class 5, EN 60228) |
| Conductor Size | 45 × 0.25 mm |
| Nominal Cross Section | 2 × 2.5 sq mm |
| Rated Voltage | 300 / 500 V |
| Operating Temperature | −30 °C ~ +90 °C |
| Outer Color | Red RAL 3000 |
| Applicable Standards | IEC 60331-21 (FE90), BS 6387 CAT B/C, IEC 60332-1-2, IEC 60332-3-24, EN 50266-2-4, CE, RoHS |
| Component | Material / Description | Standard | Dimensions |
|---|---|---|---|
| Conductor | Stranded Bare Copper | EN 60228 | 45 × 0.25 mm |
| DC Resistance (20 °C) | — | EN 60228 | 7.98 Ω/km |
| Insulation | Silicone Rubber (Heat Resistant) | IEC/EN 60811-203 | 0.5 mm thick |
| Insulation Diameter | — | IEC/EN 60811-201 | 3.1 ± 0.1 mm |
| Insulation Colors | Brown / White | — | — |
| Insulation Resistance | > 200 MΩ/km | — | — |
| Overall Screen | Aluminum Foil (Overlapped) | — | 0.04 × 24 mm |
| Drain Wire | Tinned Copper (7 × 0.3 mm) | — | — |
| Outer Sheath | LSZH (Low Smoke Zero Halogen) | IEC/EN 60811-202 | 0.7 mm thick |
| Outer Diameter | — | IEC/EN 60811-203 | 7.8 ± 0.2 mm |
| Pitch of Twist | — | — | 136 ± 10 mm |
| Inductance | — | — | 2.3 mH/km |
| High Voltage Test | EN 50288-7 | 2.0 kV / 1 min | — |
| Test Item | Standard | Description / Requirement |
|---|---|---|
| Fire Resistance | IEC 60331-21 (FE90) / BS 6387 CAT B, CAT C | Maintains circuit integrity for 90 min at 750–850 °C |
| Flame Propagation | IEC 60332-1-2 / IEC 60332-3-24 / EN 50266-2-4 | Restricts flame spread on single and bunched cables |
| Smoke Density | IEC 61034-1/2 | Low smoke emission ensures visibility during fire |
| Corrosive Gas Emission | IEC 60754-1/2 / EN 50267 | Low acid gas release, halogen-free |
| RoHS Compliance | EU Directive 2011/65/EU | Confirmed (Pb, Cd, Hg, Cr⁶⁺, PBB, PBDE Free) |
Insulation Resistance: > 200 MΩ/km
Voltage Withstand: 2.0 kV (1 min)
Inductance: 2.3 mH/km
Operating Temperature: −30 °C ~ +90 °C
Minimum Bending Radius: 10 × OD
Fire Survival Duration: 90 min (FE90)
Designed for fire protection and emergency circuits requiring consistent operation during fire
Fire-alarm and emergency lighting systems
Smoke extraction and sprinkler control
Tunnels, hospitals, airports, and industrial facilities
FE90 Fire Resistance: Maintains circuit integrity for 90 minutes at 850 °C
LSZH Outer Sheath: Low smoke and non-toxic gas emission
Silicone + Aluminum Shield: Excellent heat and EMI protection
✅ Certified Safety: Complies with IEC, BS, EN, CE and RoHS standards
Fire Resistant Cable 2 × 2.5 sq mm | IEC 60331-21 (FE90) / LSZH / BS 6387 Compliant (Red RAL 3000)

| Item | Specification |
|---|---|
| Product Name | Fire Resistant Cable |
| Model No. | FR331-0S-0225 |
| Construction Type | CU / FR / OS / LSZH (Overall Screened) |
| Conductor Material | Stranded Bare Copper (Class 5, EN 60228) |
| Conductor Size | 45 × 0.25 mm |
| Nominal Cross Section | 2 × 2.5 sq mm |
| Rated Voltage | 300 / 500 V |
| Operating Temperature | −30 °C ~ +90 °C |
| Outer Color | Red RAL 3000 |
| Applicable Standards | IEC 60331-21 (FE90), BS 6387 CAT B/C, IEC 60332-1-2, IEC 60332-3-24, EN 50266-2-4, CE, RoHS |
| Component | Material / Description | Standard | Dimensions |
|---|---|---|---|
| Conductor | Stranded Bare Copper | EN 60228 | 45 × 0.25 mm |
| DC Resistance (20 °C) | — | EN 60228 | 7.98 Ω/km |
| Insulation | Silicone Rubber (Heat Resistant) | IEC/EN 60811-203 | 0.5 mm thick |
| Insulation Diameter | — | IEC/EN 60811-201 | 3.1 ± 0.1 mm |
| Insulation Colors | Brown / White | — | — |
| Insulation Resistance | > 200 MΩ/km | — | — |
| Overall Screen | Aluminum Foil (Overlapped) | — | 0.04 × 24 mm |
| Drain Wire | Tinned Copper (7 × 0.3 mm) | — | — |
| Outer Sheath | LSZH (Low Smoke Zero Halogen) | IEC/EN 60811-202 | 0.7 mm thick |
| Outer Diameter | — | IEC/EN 60811-203 | 7.8 ± 0.2 mm |
| Pitch of Twist | — | — | 136 ± 10 mm |
| Inductance | — | — | 2.3 mH/km |
| High Voltage Test | EN 50288-7 | 2.0 kV / 1 min | — |
| Test Item | Standard | Description / Requirement |
|---|---|---|
| Fire Resistance | IEC 60331-21 (FE90) / BS 6387 CAT B, CAT C | Maintains circuit integrity for 90 min at 750–850 °C |
| Flame Propagation | IEC 60332-1-2 / IEC 60332-3-24 / EN 50266-2-4 | Restricts flame spread on single and bunched cables |
| Smoke Density | IEC 61034-1/2 | Low smoke emission ensures visibility during fire |
| Corrosive Gas Emission | IEC 60754-1/2 / EN 50267 | Low acid gas release, halogen-free |
| RoHS Compliance | EU Directive 2011/65/EU | Confirmed (Pb, Cd, Hg, Cr⁶⁺, PBB, PBDE Free) |
Insulation Resistance: > 200 MΩ/km
Voltage Withstand: 2.0 kV (1 min)
Inductance: 2.3 mH/km
Operating Temperature: −30 °C ~ +90 °C
Minimum Bending Radius: 10 × OD
Fire Survival Duration: 90 min (FE90)
Designed for fire protection and emergency circuits requiring consistent operation during fire
Fire-alarm and emergency lighting systems
Smoke extraction and sprinkler control
Tunnels, hospitals, airports, and industrial facilities
FE90 Fire Resistance: Maintains circuit integrity for 90 minutes at 850 °C
LSZH Outer Sheath: Low smoke and non-toxic gas emission
Silicone + Aluminum Shield: Excellent heat and EMI protection
✅ Certified Safety: Complies with IEC, BS, EN, CE and RoHS standards