FR6387-OS-0215

  • FR6387-OS

  • Zion communication

  • Fire Cable

  • UL, ETL, CE,CPR, RoHS

  • 100m,500m,500ft,1000ft

  • roll, wooden spool, carton, pallet

  • 10KM

  • Normally 15 working days

  • NINGBO, SHANGHAI

  • T/T, L/C at sight, D/P at sight

Availability:

 ZION COMMUNICATION — FR6387-OS-0215

Fire Resistant Cable 2×1.5 sqmm | BS6387 / IEC60331 / LSZH (Red RAL3000)


FR6387-OS Fire Resistant Cable structure


General Information

Item Specification
Product Name Fire Resistant Cable
Model No. FR6387-OS-0215
Construction Type CU / FR / OS / LSHF
Conductor Material Stranded Bare Copper (Class 5, EN 60228)
Conductor Size 28 × 0.25 mm
Nominal Cross Section 2 × 1.5 sqmm
Rated Voltage 300 / 500 V
Operating Temperature −30 °C ~ +90 °C
Color Red RAL 3000
Standard References IEC 60331-21 (FE180), BS 6387 CAT B / C, IEC 60332-1-2, IEC 60332-3-24, EN 50200 PH120, CE, RoHS


Construction Details

Component Material / Description Standard Dimensions
Conductor Stranded Bare Copper EN 60228 28 × 0.25 mm
DC Resistance 13.3 Ω/km EN 60228
Insulation Silicone Heat-Resistant Compound IEC/EN 60811-203 0.45 mm thick
Insulation Diameter IEC/EN 60811-201 2.4 ± 0.1 mm
Insulation Colors Brown / White
Insulation Resistance > 200 MΩ/km
Fire Resistant Layer Mica Tape 0.14 × 22 mm
Overall Screen Aluminum Foil (Overlapped) 0.04 × 22 mm
Drain Wire Tinned Copper 7 × 0.3 mm
Outer Sheath LSZH (Low Smoke Halogen Free) IEC/EN 60811-202 0.6 mm thick
Outer Diameter IEC/EN 60811-203 6.5 ± 0.2 mm
Pitch of Twist 106 ± 10 mm
Inductance 2.3 mH/km
High Voltage Test EN 50288-7 2.0 kV


Fire and Safety Compliance

Test Standard Applied Description / Requirement
Fire Test IEC 60331-21 (FE180), BS 6387 CAT B/C Maintains circuit integrity at 750–950 °C
Flame Test IEC 60332-1-2 / IEC 60332-3-24 / EN 50266-2-4 Controls flame spread on single & bunched cables
Smoke Density IEC 61034-1/2 Ensures low smoke emission & high visibility
Corrosive Gas Measurement IEC 60754-1/2 / EN 50267 Verifies low halogen acid gas release
RoHS Compliance EU Directive 2011/65/EU Confirmed (Pb, Cd, Hg, Cr⁶⁺, PBB, PBDE Free)


Electrical & Mechanical Performance

  • Voltage Withstand Test: 2 kV / 1 min (EN 50288-7)

  • Insulation Resistance: > 200 MΩ/km

  • Operating Temperature Range: −30 °C to +90 °C

  • Minimum Bending Radius: 10 × Cable OD

  • Tensile Strength: > 15 N/mm² (typical)

Application

Designed for emergency power and control circuits in critical infrastructure requiring circuit survival under fire exposure:

  • Fire alarm & emergency lighting systems

  • Smoke extraction fans

  • Sprinkler & pump controls

  • Tunnels, metro stations, hospitals, data centers, and industrial buildings

Product Highlights

Fire Resistant (FE180 / PH120): Keeps power and signal continuity during fire.

LSZH Jacket: Minimizes smoke and toxic gas emissions.

Mica + Silicone + Copper System: Ensures superior dielectric stability under extreme heat.

⚙️ Flexible Structure: Easy to install in conduits or cable trays.

Fully Certified: CE & RoHS compliant for international projects.


Previous: 
Next: 
We use cookies to enable all functionalities for the best performance during your visit and to improve our services by giving us some insight into how the website is being used. Continued use of our website without changing your browser settings confirms your acceptance of these cookies. For details, please see our privacy policy.
×