GJXH
FTTH
ISO9001
1km/Spool
Wooden Spool ,Φ280*280mm
100km
Normally 15 working days
NINGBO CHINA
30%TT as deposit,70%Balance before shipping.
Availability: | |
---|---|
GJXH-FTTH Flat Drop Cable 2.0×3.0mm
· Cable Type: GJXH-1, GJXH-2, GJXH-4 (Single Core, 2 Core, 4 Core)
· Fiber Type: G.657.A2
· Fiber Colors:
o GJXH-1: Blue
o GJXH-2: Blue, Orange
o GJXH-4: Blue, Orange, Green, Brown
· Cable Diameter: (2.0 ± 0.05) x (3.0 ± 0.1) mm
· Load-bearing Strength Member: None
· Cable Strength Member: Phosphated Steel (2 strands, 0.40mm)
· Outer Sheath Material: LSZH (Low Smoke Zero Halogen)
· Minimum Bending Radius:
o Operation: 30D (where D is the cable diameter)
o Using: 15D
· Tensile Strength:
o Long-term: 100N
o Short-term: 200N
· Crush Strength:
o Long-term: 1000N/100mm
o Short-term: 2000N/100mm
· Attenuation:
o 1310nm: ≤0.36dB/km
o 1550nm: ≤0.22dB/km
· Cut-off Wavelength: ≤1260nm
· Storage Temperature: -40°C to +70°C
· Operating Temperature: -30°C to +60°C
· ZION: Manufacturer’s brand (can be customized to the client's brand if needed).
· 2024: Year of manufacture.
· FTTH: Type of cable (Fiber to the Home).
· XX (G.657A): Number of cores (e.g., 1 core, 2 cores, etc.) with the fiber type specified as G.657A (a single-mode optical fiber standard).
· XXXXm: Length of the cable in meters.
*The marking is printed every 1 meter;
● The color of marking is white, but if the remarking is necessary, the yellow color marking shall be printed newly on a different position.
● An occasional unclear of length marking is permitted if both of the neighboring markings are clear;
● The both cable ends are sealed with heat shrinkable end caps to prevent water ingress.
The properties of single mode optical fiber (ITU-T Rec. G.657)
· MFD (Mode Field Diameter) at 1310nm: 8.2 - 9.0 mm
· Cladding Diameter: 125.0 ± 0.7 mm
· Cladding Non-circularity: ≤ 1.0% (ensures the cladding is nearly circular)
· Cladding to Core Concentricity Error: ≤ 0.5 mm (ensures proper alignment between the core and cladding)
· Secondary Coating Diameter: 245.0 ± 10.0 mm
· Secondary Coating to Cladding Concentricity Error: ≤ 12.0 mm
· Fiber Curl: ≥ 4.0 m (indicates minimum allowable radius for fiber bending)
· At 1310nm: ≤ 0.34 dB/km
· At 1383nm: ≤ 0.31 dB/km
· At 1383nm (after H2 aging): Δ ≤ 0.01 dB/km (indicates minimal degradation after aging)
· At 1550nm: ≤ 0.20 dB/km
· At 1625nm: ≤ 0.23 dB/km
· Point Discontinuity at 1310nm and 1550nm: ≤ 0.02 dB (ensures minimal discontinuities at these wavelengths)
· At 1310nm: 1150 ≤ λc ≤ 1330 nm (indicates the operational range for fiber cut-off)
· At 1310 - 1324 nm: 1300 - 1324 nm (range of wavelengths with minimal chromatic dispersion)
· At 1288-1339 nm: ≤ 3.5 ps/(nm·km)
· At 1271-1360 nm: ≤ 5.3 ps/(nm·km)
· At 1550 nm: ≤ 18 ps/(nm·km)
· At 1625 nm: ≤ 22 ps/(nm·km)
· Fiber PMD: ≤ 0.2 ps/km¹/²
· Link PMD: ≤ 0.1 ps/km¹/² (for longer transmission distances)
● Attenuation vs. Wavelength maximum increase of the att. in 1285-1330nm reference the att. at 1310nm 0.03dB/km; maximum increase of the att. in 1525-1575nm reference the att. at 1550nm 0.02dB/km.
● Attenuation from out end- attenuation from inner end 0.05dB/km ; max segment loss-avg loss0.03dB/km.(OTDR)
· Strain: ≥ 2.0% (indicates the strain at which the proof stress is defined)
· Proof Tension Stress: ≥ 19.76 N (the force at which the fiber undergoes permanent deformation)
· 15 mm (the minimum radius the fiber can be bent without damaging it)
· For 10 turns with D=30mm:
o At 1550 nm: α ≤ 0.25 dB
o At 1625 nm: α ≤ 1.0 dB
· For 1 turn with D=20mm:
o At 1550 nm: α ≤ 0.75 dB
o At 1625 nm: α ≤ 1.5 dB
o These values represent the additional signal loss (attenuation) induced when the fiber is bent. A smaller bending radius or more turns results in higher attenuation.
· Peak Value (F): 1 ≤ F ≤ 8.9 N (force required to strip the coating)
· Average Value (F): 1 ≤ F ≤ 5 N (average stripping force required)
· Nd ≥ 20 (a measure of the fiber's resistance to dynamic fatigue, indicating the number of cycles the fiber can withstand under stress before breaking)
· sf ≥ 3.8 GPa (the breaking strength of the fiber, measured in gigapascals, indicating the fiber's ability to withstand tension)
Packing
● Each single length of cable shall be reeled on Plastic Drum.
● Drum length: Standard drum length is 3000m±2% or design as per client inquiry ;
Drum Marking (can according to the requirement in the technical specification)
-Manufacturer name;
-Manufacturing year and month;
-Roll-direction arrow;
-Cable outer end position indicating arrow;
-The word “OPTICAL FIBER CABLE”;
-Cable type and size;
-Drum number;
-Drum length;
-Gross / net weight;
-Origin, The word “MADE IN CHINA”;
-Caution plate indicating the correct method for loading, unloading and convey the cable;
-Other customer information such as contract no., project no., and delivery destination. (if needed)
Cable identification documents
-Product qualified certificate;
-Test report.
GJXH-FTTH Flat Drop Cable 2.0×3.0mm
· Cable Type: GJXH-1, GJXH-2, GJXH-4 (Single Core, 2 Core, 4 Core)
· Fiber Type: G.657.A2
· Fiber Colors:
o GJXH-1: Blue
o GJXH-2: Blue, Orange
o GJXH-4: Blue, Orange, Green, Brown
· Cable Diameter: (2.0 ± 0.05) x (3.0 ± 0.1) mm
· Load-bearing Strength Member: None
· Cable Strength Member: Phosphated Steel (2 strands, 0.40mm)
· Outer Sheath Material: LSZH (Low Smoke Zero Halogen)
· Minimum Bending Radius:
o Operation: 30D (where D is the cable diameter)
o Using: 15D
· Tensile Strength:
o Long-term: 100N
o Short-term: 200N
· Crush Strength:
o Long-term: 1000N/100mm
o Short-term: 2000N/100mm
· Attenuation:
o 1310nm: ≤0.36dB/km
o 1550nm: ≤0.22dB/km
· Cut-off Wavelength: ≤1260nm
· Storage Temperature: -40°C to +70°C
· Operating Temperature: -30°C to +60°C
· ZION: Manufacturer’s brand (can be customized to the client's brand if needed).
· 2024: Year of manufacture.
· FTTH: Type of cable (Fiber to the Home).
· XX (G.657A): Number of cores (e.g., 1 core, 2 cores, etc.) with the fiber type specified as G.657A (a single-mode optical fiber standard).
· XXXXm: Length of the cable in meters.
*The marking is printed every 1 meter;
● The color of marking is white, but if the remarking is necessary, the yellow color marking shall be printed newly on a different position.
● An occasional unclear of length marking is permitted if both of the neighboring markings are clear;
● The both cable ends are sealed with heat shrinkable end caps to prevent water ingress.
The properties of single mode optical fiber (ITU-T Rec. G.657)
· MFD (Mode Field Diameter) at 1310nm: 8.2 - 9.0 mm
· Cladding Diameter: 125.0 ± 0.7 mm
· Cladding Non-circularity: ≤ 1.0% (ensures the cladding is nearly circular)
· Cladding to Core Concentricity Error: ≤ 0.5 mm (ensures proper alignment between the core and cladding)
· Secondary Coating Diameter: 245.0 ± 10.0 mm
· Secondary Coating to Cladding Concentricity Error: ≤ 12.0 mm
· Fiber Curl: ≥ 4.0 m (indicates minimum allowable radius for fiber bending)
· At 1310nm: ≤ 0.34 dB/km
· At 1383nm: ≤ 0.31 dB/km
· At 1383nm (after H2 aging): Δ ≤ 0.01 dB/km (indicates minimal degradation after aging)
· At 1550nm: ≤ 0.20 dB/km
· At 1625nm: ≤ 0.23 dB/km
· Point Discontinuity at 1310nm and 1550nm: ≤ 0.02 dB (ensures minimal discontinuities at these wavelengths)
· At 1310nm: 1150 ≤ λc ≤ 1330 nm (indicates the operational range for fiber cut-off)
· At 1310 - 1324 nm: 1300 - 1324 nm (range of wavelengths with minimal chromatic dispersion)
· At 1288-1339 nm: ≤ 3.5 ps/(nm·km)
· At 1271-1360 nm: ≤ 5.3 ps/(nm·km)
· At 1550 nm: ≤ 18 ps/(nm·km)
· At 1625 nm: ≤ 22 ps/(nm·km)
· Fiber PMD: ≤ 0.2 ps/km¹/²
· Link PMD: ≤ 0.1 ps/km¹/² (for longer transmission distances)
● Attenuation vs. Wavelength maximum increase of the att. in 1285-1330nm reference the att. at 1310nm 0.03dB/km; maximum increase of the att. in 1525-1575nm reference the att. at 1550nm 0.02dB/km.
● Attenuation from out end- attenuation from inner end 0.05dB/km ; max segment loss-avg loss0.03dB/km.(OTDR)
· Strain: ≥ 2.0% (indicates the strain at which the proof stress is defined)
· Proof Tension Stress: ≥ 19.76 N (the force at which the fiber undergoes permanent deformation)
· 15 mm (the minimum radius the fiber can be bent without damaging it)
· For 10 turns with D=30mm:
o At 1550 nm: α ≤ 0.25 dB
o At 1625 nm: α ≤ 1.0 dB
· For 1 turn with D=20mm:
o At 1550 nm: α ≤ 0.75 dB
o At 1625 nm: α ≤ 1.5 dB
o These values represent the additional signal loss (attenuation) induced when the fiber is bent. A smaller bending radius or more turns results in higher attenuation.
· Peak Value (F): 1 ≤ F ≤ 8.9 N (force required to strip the coating)
· Average Value (F): 1 ≤ F ≤ 5 N (average stripping force required)
· Nd ≥ 20 (a measure of the fiber's resistance to dynamic fatigue, indicating the number of cycles the fiber can withstand under stress before breaking)
· sf ≥ 3.8 GPa (the breaking strength of the fiber, measured in gigapascals, indicating the fiber's ability to withstand tension)
Packing
● Each single length of cable shall be reeled on Plastic Drum.
● Drum length: Standard drum length is 3000m±2% or design as per client inquiry ;
Drum Marking (can according to the requirement in the technical specification)
-Manufacturer name;
-Manufacturing year and month;
-Roll-direction arrow;
-Cable outer end position indicating arrow;
-The word “OPTICAL FIBER CABLE”;
-Cable type and size;
-Drum number;
-Drum length;
-Gross / net weight;
-Origin, The word “MADE IN CHINA”;
-Caution plate indicating the correct method for loading, unloading and convey the cable;
-Other customer information such as contract no., project no., and delivery destination. (if needed)
Cable identification documents
-Product qualified certificate;
-Test report.