EN50200 Fire alarm cable
hellosignal
7110419
Fire Alarm Cable
UL, ETL, CE, CPR, RoHS, LPCB
100m,500m,500ft,1000ft
roll, wooden spool, carton, pallet
10KM
Normally 15 working days
NINGBO, SHANGHAI
T/T, L/C at sight, D/P at sight
Availability: | |
---|---|
PH30 19×1.5mm²
Fire Alarm Cables
NO.7110419
Conductor:
1.5mm(sqm) Plain annealed copper wire,
class 1,2 or 5 according to EN60228.
Insulation:
Fire-resistant silicone rubber
BS 6387 CWZ,EN 50200 PH30,IEC 60331
Dia.over Dielectric:12x(0.0102"(2.6 mm))
Insulation Color:
Brn/Blk/Whi
Separator:
PET Foil
Drain Wire:
0.80 mm Solid tinned copper
Shield:
Aluminum PET (100% Coverage 20% overlapping)
Jacket:
FR-LSZH (Red or White)
Dia.over Jacket: 0.669''±0.006''(17.0±0.15mm)
HFFR EN 502902,BS7655 LTS1/LTS3
Print Legend:
HELLOSIGNAL Fire Alarm Cable PH30 1.0mm² 19 Cores Class N
BC BS 50200:2006 NO.7110419 ××××M/FT
Min.Bend Radius: 8×Diameter
Min.Insulation resistance: 200 MΩ/km
Max.Working Temperature: -30℃~+90℃
Test voitage: 2000 V
Max.Operating voitage: 300 V / 600 V
Max. resistance of Cond:
Class1,2: 12Ω/km
Class5: 12.9Ω/km
This cable meets multiple fire performance, insulation integrity, and environmental safety standards, including:
Fire Resistance & Flame Retardancy:
BS 6387 CWZ (fire survival test for cables)
EN 50200 PH30 (fire resistance for 30 minutes)
IEC 60331 (circuit integrity under fire conditions)
BS 4066 Part 1 & 3
EN 50266-2-4 (flame propagation tests)
IEC/EN 60332-1 & IEC 60332-3-24 (fire propagation tests)
Smoke, Gas, and Toxicity Tests:
IEC/EN 61034 (smoke density test)
IEC 60754-2 (halogen acid gas test)
BS EN 50267-2-2 (corrosive gas emission)
HD 606
Package: 100M/Wooden Spool,200M/Wooden Spool,500M/Wooden Spool
Delivery time: Normally 25 days after received the deposit.
Brand: HELLOSIGNAL® OR OEM
PH30 19×1.5mm²
Fire Alarm Cables
NO.7110419
Conductor:
1.5mm(sqm) Plain annealed copper wire,
class 1,2 or 5 according to EN60228.
Insulation:
Fire-resistant silicone rubber
BS 6387 CWZ,EN 50200 PH30,IEC 60331
Dia.over Dielectric:12x(0.0102"(2.6 mm))
Insulation Color:
Brn/Blk/Whi
Separator:
PET Foil
Drain Wire:
0.80 mm Solid tinned copper
Shield:
Aluminum PET (100% Coverage 20% overlapping)
Jacket:
FR-LSZH (Red or White)
Dia.over Jacket: 0.669''±0.006''(17.0±0.15mm)
HFFR EN 502902,BS7655 LTS1/LTS3
Print Legend:
HELLOSIGNAL Fire Alarm Cable PH30 1.0mm² 19 Cores Class N
BC BS 50200:2006 NO.7110419 ××××M/FT
Min.Bend Radius: 8×Diameter
Min.Insulation resistance: 200 MΩ/km
Max.Working Temperature: -30℃~+90℃
Test voitage: 2000 V
Max.Operating voitage: 300 V / 600 V
Max. resistance of Cond:
Class1,2: 12Ω/km
Class5: 12.9Ω/km
This cable meets multiple fire performance, insulation integrity, and environmental safety standards, including:
Fire Resistance & Flame Retardancy:
BS 6387 CWZ (fire survival test for cables)
EN 50200 PH30 (fire resistance for 30 minutes)
IEC 60331 (circuit integrity under fire conditions)
BS 4066 Part 1 & 3
EN 50266-2-4 (flame propagation tests)
IEC/EN 60332-1 & IEC 60332-3-24 (fire propagation tests)
Smoke, Gas, and Toxicity Tests:
IEC/EN 61034 (smoke density test)
IEC 60754-2 (halogen acid gas test)
BS EN 50267-2-2 (corrosive gas emission)
HD 606
Package: 100M/Wooden Spool,200M/Wooden Spool,500M/Wooden Spool
Delivery time: Normally 25 days after received the deposit.
Brand: HELLOSIGNAL® OR OEM