RG6 2C
hellosignal
7102004
Coaxial Cable
75 ohm
UL, ETL, CE, RoHS
100m, 305m,500m,1000m,500ft,1000ft
roll, wooden spool, carton, pallet
30KM
Normally 15 working days
NINGBO, SHANGHAI
T/T, L/C at sight, D/P at sight
Availability: | |
---|---|
75 Ohm CCTV coaxial Cable NO.7102004 | ||
Construction Parameters: | ||
Inner Conductor | 1.02mm/0.04"/18AWG Copper | |
Dielectric | 4.32mm Foam FEP | |
Shield 1 | Bonded Aluminum Foil Shield | |
Shield 2 | BC braid wire 95% coverage | |
Jacket | 5.9mm PVC-CMP | |
Power Wire Conductor | 2x18AWG/(7*0.38 mm) BC | |
Power wire Diameter of insulation | 1.6mmPVC-CMP (Red,Black) | |
Jacket | 3.8mmPVC-CMP | |
Application | For Use in Longer CCTV Run Lengths | |
Electrical Characteristics: | ||
Inner Conductor Resistance | The Max. at 20℃ shall be < 21.2 Ω/km (6.96 Ω/kft) | |
Capacitance | 52 ±3 pF/m 17±0.3 pF/ft | |
Impedance | 75 ± 3 Ω | |
Return loss | between 5 and 1000MHz: > 22dB | |
Velocity of Propagation | 0.85 | |
Sparker Test (VAC) | 4 | |
Mechanical and Envrionmental Properties | ||
Cable bend radius | 10 times the cable diameter | |
Operating Temp Range | -20 ℃ to 75℃ | |
Cable diamensions | 5.9×3.8mm | |
Cross Section | ||
Attenuation(20℃): | ||
Frequency (MHZ) | Max Attenuation(dB/100ft) | Max Attenuation (dB/100m) |
1 | 0.50 | 1.64 |
10 | 0.92 | 3.02 |
50 | 1.75 | 5.74 |
100 | 2.60 | 8.52 |
200 | 3.80 | 12.46 |
400 | 5.50 | 18.03 |
700 | 7.60 | 24.92 |
900 | 8.90 | 29.18 |
1000 | 9.30 | 30.49 |
1200 | 10.60 | 34.75 |
1450 | 12.00 | 39.34 |
1800 | 13.60 | 44.59 |
2200 | 14.80 | 48.52 |
3000 | 18.00 | 59.02 |
Order Informations: | ||
Marking | HELLOSIGNAL RG6/U+2C18AWG CMP Figure 8 | |
Package | Inquired Length on Reel,Pull Box,Plastic Spool,wooden Spool,pallet … | |
Delivery time | Normally 25 days after received the deposit. | |
Brand | HELLOSIGNAL® OR OEM | |
75 Ohm CCTV coaxial Cable NO.7102004 | ||
Construction Parameters: | ||
Inner Conductor | 1.02mm/0.04"/18AWG Copper | |
Dielectric | 4.32mm Foam FEP | |
Shield 1 | Bonded Aluminum Foil Shield | |
Shield 2 | BC braid wire 95% coverage | |
Jacket | 5.9mm PVC-CMP | |
Power Wire Conductor | 2x18AWG/(7*0.38 mm) BC | |
Power wire Diameter of insulation | 1.6mmPVC-CMP (Red,Black) | |
Jacket | 3.8mmPVC-CMP | |
Application | For Use in Longer CCTV Run Lengths | |
Electrical Characteristics: | ||
Inner Conductor Resistance | The Max. at 20℃ shall be < 21.2 Ω/km (6.96 Ω/kft) | |
Capacitance | 52 ±3 pF/m 17±0.3 pF/ft | |
Impedance | 75 ± 3 Ω | |
Return loss | between 5 and 1000MHz: > 22dB | |
Velocity of Propagation | 0.85 | |
Sparker Test (VAC) | 4 | |
Mechanical and Envrionmental Properties | ||
Cable bend radius | 10 times the cable diameter | |
Operating Temp Range | -20 ℃ to 75℃ | |
Cable diamensions | 5.9×3.8mm | |
Cross Section | ||
Attenuation(20℃): | ||
Frequency (MHZ) | Max Attenuation(dB/100ft) | Max Attenuation (dB/100m) |
1 | 0.50 | 1.64 |
10 | 0.92 | 3.02 |
50 | 1.75 | 5.74 |
100 | 2.60 | 8.52 |
200 | 3.80 | 12.46 |
400 | 5.50 | 18.03 |
700 | 7.60 | 24.92 |
900 | 8.90 | 29.18 |
1000 | 9.30 | 30.49 |
1200 | 10.60 | 34.75 |
1450 | 12.00 | 39.34 |
1800 | 13.60 | 44.59 |
2200 | 14.80 | 48.52 |
3000 | 18.00 | 59.02 |
Order Informations: | ||
Marking | HELLOSIGNAL RG6/U+2C18AWG CMP Figure 8 | |
Package | Inquired Length on Reel,Pull Box,Plastic Spool,wooden Spool,pallet … | |
Delivery time | Normally 25 days after received the deposit. | |
Brand | HELLOSIGNAL® OR OEM | |