Please Select Product Type Please Select Product Type
  • Fiber Optic Cables
    • Optical Fibers

        No classification

    • Outdoor Fiber Optic Cables
      • ADSS cable
        • ADSS Single jacket
          • ADSS 80M Single Sheath
          • ADSS 100M Single Sheath
          • ADSS 120M Single Sheath
        • ADSS Double sheath

            No classification

      • OPGW

          No classification

      • Duct Fiber Optic Cable

          No classification

      • Direct Buried Fiber Optic Cable

          No classification

      • Air Blown Micro Cable

          No classification

    • FTTH Cables & Assemblies
      • FTTH Drop Cable

          No classification

      • FTTH Drop Patch Cord

          No classification

    • Indoor Fiber Optic Cables
      • Building Cabling Fiber

          No classification

      • Fire-Resistant Fiber Cable

          No classification

    • Fiber Connectivity
      • Fiber Patch Cable
        • LC Fiber Patch Cable
          • LC to LC Fiber Patch Cord
          • LC to SC Fiber Patch Cord
          • LC to FC Fiber Patch Cord
          • LC to ST Fiber Patch Cord
        • SC Fiber Patch Cable
          • SC to FC Fiber Patch Cord
          • SC to SC Fiber Patch Cord
          • SC to ST Fiber Patch Cord
        • FC Fiber Patch Cable

            No classification

        • ST Fiber Patch Cable

            No classification

        • MU Fiber Patch Cable

            No classification

        • Fiber Pigtails

            No classification

        • MTRJ Patch Cords

            No classification

        • SMA Patch Cords

            No classification

      • High-Density MPO Cabling
        • MPO Patch Cords

            No classification

        • MPO Trunk Cables

            No classification

        • MPO-LC Harness Cables

            No classification

        • MPO Fan-Out Cables

            No classification

        • MPO / MTP Loopback Modules

            No classification

        • MPO Patch Panels & Cassettes

            No classification

      • Fiber Optic Tether System
        • FPV Drone

            No classification

        • FPV Fiber Optic Spool

            No classification

        • Fiber Optic Guidance Wire

            No classification

    • Solutions by Application
      • Aerial Fiber Optic Cable

          No classification

      • Rural Network Fiber Optic Cable

          No classification

      • Space-Saving Fiber Optic Cable

          No classification

      • Distributed Base Station Fiber Optic Cable

          No classification

      • Rodent Resistant Fiber Optic Cable

          No classification

  • Fiber Optic Tools
    • Fiber Optic Installation Tools/Accessories/Fittings
      • ADSS Cable Accessories
        • ADSS Cable Guy Grips

            No classification

        • ADSS Cable Suspension Grips

            No classification

      • OPGW Cable Accessories
        • OPGW Cable Guy Grips

            No classification

        • OPGW Cable Suspension Grips

            No classification

      • Banding & Fitting Tools
        • Stainless steel strip &buckle

            No classification

        • Stainless Banding Tool

            No classification

      • Pole Mounting Supports
        • Aluminum hoop&Pole Bracket

            No classification

        • Hoop Retractor&Pole Brackets

            No classification

      • Cable Fittings
        • Fittings

            No classification

        • Immobility Clamp

            No classification

    • FTTH Fiber Optic Tools
      • FTTH Flat Drop Cable Clamps
        • FTTH stainless steel flat drop cable clamp

            No classification

        • FTTH nylon cable flat drop cable clamp

            No classification

        • FTTH combination flat drop cable clamp

            No classification

      • FTTH Installation Accessories
        • FTTH Hook

            No classification

      • FTTX ADSS Suspension & Tension Clamps
        • FTTX ADSS Suspension clamp

            No classification

        • FTTX ADSS Tension clamp

            No classification

    • Fiber Termination Tools

        No classification

    • Fiber Optic Test Tools

        No classification

    • OTDR Accessories

        No classification

    • Fiber Optic Cleaning Tools

        No classification

  • LAN/Ethernet Cable
    • CAT8

        No classification

    • CAT7 / CAT7A
      • CAT7

          No classification

      • CAT7A

          No classification

    • CAT6A
      • U/UTP

          No classification

      • U/FTP

          No classification

      • F/UTP

          No classification

      • F/FTP

          No classification

      • S/FTP

          No classification

      • CAT6A AMOUR/CST

          No classification

    • CAT6
      • U/UTP

          No classification

      • F/UTP

          No classification

      • SF/UTP

          No classification

      • Dual

          No classification

      • Armour CAT6

          No classification

    • CAT5E
      • U/UTP

          No classification

      • F/UTP

          No classification

      • SF/UTP

          No classification

      • Dual

          No classification

    • Copper Patch Cord Cable
      • CAT5E

          No classification

      • CAT6

          No classification

      • CAT6A

          No classification

      • CAT7

          No classification

      • CAT7A

          No classification

      • CAT8

          No classification

      • Special type

          No classification

    • Ethernet Plenum Cable

        No classification

    • Network Cable

        No classification

    • Copper Trunk Cable

        No classification

    • Direct-Burial Outdoor Ethernet Cables

        No classification

    • Ethernet Installation Accessories & Tools

        No classification

  • Coaxial Cable
    • Low Loss Cable

        No classification

    • RF Corrugated Coax Cable
      • 1/4"

          No classification

      • 3/8"

          No classification

      • 1/2"

          No classification

      • 7/8"

          No classification

      • 1 1/4"

          No classification

      • 1 5/8"

          No classification

    • Radiating Leaky Coaxial Cable

        No classification

    • RG MIL-C-17 Cable

        No classification

    • PTFE-FEP Coaxial Cable

        No classification

    • D-FB Coax Cable
      • D-FB cable

          No classification

      • Connectors for D-FB cable

          No classification

      • Grounding Kit, Clamp, Weatherproof for D-FB cable

          No classification

    • 75 ohm Coaxial Cable
      • RG6 coax cable
        • RG6 S

            No classification

        • RG6 Tri

            No classification

        • RG6 Q

            No classification

        • RG6 Dual

            No classification

      • RG59 coax cable
        • RG59 S

            No classification

        • RG59 Tri

            No classification

        • RG59 Q

            No classification

      • RG11
        • RG11 S

            No classification

        • RG11 Tri

            No classification

        • RG11 Q

            No classification

      • SAT coax cable

          No classification

      • HD coaxial cable

          No classification

      • VHF Leaky Feeder Cable

          No classification

      • Trunk cable/Hardline cable
        • PS

            No classification

        • QR

            No classification

      • CT coax cable

          No classification

      • KX coax cable

          No classification

      • VATC coax cable

          No classification

      • PK75 coax cable

          No classification

    • Plenum Coaxial Cable

        No classification

    • EN 50117 Coaxial Cable
      • Broadband double shield SA Class A++ >105dB

          No classification

      • Broadband Triple shield SA Class A++ >105dB

          No classification

      • Digital Drop shield SA Class A+>95dB

          No classification

      • Digital Drop shield SA Class A>85dB

          No classification

    • Coaxial Jumper Cables
      • 1/2" Super Flex Jumper Cable

          No classification

      • 1/2" Feeder Jumper Cable

          No classification

      • 3/8" Super Flex Jumper Cable

          No classification

      • 1/4" Super Flex Jumper Cable

          No classification

      • RG141 Jumper Cable

          No classification

      • RG142 Jumer Cable

          No classification

      • RG58 Jumper Cable

          No classification

    • 50 Ohm Coaxial Cable

        No classification

    • Semi-Flexible Series Cable

        No classification

  • Fire, Security & Alarm Cable
    • Fire Cables

        No classification

    • Fire Resistance Cable
      • EN 50200 PH30 Fire-Resistant Cable

          No classification

      • EN 50200 PH120 Fire-Resistant Cable

          No classification

      • JB-Fire Alarm Cable

          No classification

      • BS 6387 CWZ Fire-Resistant Cable

          No classification

      • BS 7629-1 Fire-Resistant Fire Alarm Cable

          No classification

      • FRLS & FRFH
        • FRLS & FRFH Unshielded

            No classification

        • FRLS & FRFH Shielded

            No classification

      • Silicon Insulation

          No classification

    • Fire Alarm Cable
      • UL Fire alarm cable-MENA

          No classification

      • UL 1424 FPL Unshielded

          No classification

      • UL 1424 FPLR Unshielded

          No classification

      • UL 1424 FPLP Unshielded

          No classification

      • UL 1424 FPL Shielded

          No classification

      • UL 1424 FPLR Shielded

          No classification

      • UL 1424 FPLP Shielded

          No classification

      • UL 1424 Solid
        • UL 1424 Solid S

            No classification

        • UL 1424 Solid U

            No classification

      • UL 1424 Stranded
        • UL 1424 Stranded U

            No classification

        • UL 1424 Stranded S

            No classification

      • UL Standard

          No classification

    • CCTV Surveillance Cable
      • Siamese Ethernet Cable

          No classification

      • Siamese Coaxial Cable
        • RG59+2c

            No classification

        • RG6+2c

            No classification

        • Other

            No classification

      • KVK CCTV Cable
        • КВК-В-1,5

            No classification

        • КВК-В-2Э

            No classification

        • КВК-П-1,5

            No classification

        • КВК-П-2Э

            No classification

      • Custom CCTV Combined Cable
        • HD

            No classification

        • PTZ

            No classification

        • RG59

            No classification

        • MENA

            No classification

      • RG6 CCTV

          No classification

      • RG59 CCTV

          No classification

      • RG11 CCTV

          No classification

      • PK75 CCTV
        • Паракс РК 75-2-110

            No classification

        • Паракс РК 75-2-111

            No classification

        • Паракс РК 75-2-122

            No classification

        • Паракс РК 75-2-13M

            No classification

        • Паракс РК 75-2-310

            No classification

        • Паракс РК 75-2-311

            No classification

        • Паракс РК 75-3-313 нг(А)

            No classification

        • Паракс РК 75-3-314 нг(А)

            No classification

        • Паракс РК 75-3-315 нг(А)

            No classification

        • Паракс РК 75-3-316 нг(А)

            No classification

        • Паракс РК 75-3-32

            No classification

        • Паракс РК 75-3-322

            No classification

      • JIS C CCTV

          No classification

      • MINI CCTV

          No classification

      • Other

          No classification

    • Burglar Alarm cable
      • Alarm, signal cable

          No classification

      • Mylar Pair Cable

          No classification

      • Solid Cond. global alarm cable

          No classification

      • Stranded Cond.unshielded global alarm cable

          No classification

      • Stranded Cond.shielded global alarm cable

          No classification

      • UL Standard security,sound, alarm cable

          No classification

      • General Purpose

          No classification

    • Access Control Cable

        No classification

    • Fire Alarm System
      • Cables De Alarma Incendio

          No classification

      • Cabos De Alarme De IncÊndio

          No classification

    • Lutron Cables

        No classification

    • Plenum Security Cables

        No classification

  • Voice, Audio & Video Cable
    • Flat Telephone Cable

        No classification

    • Circular Audio Speaker Cable

        No classification

    • Circular Shielded Audio Cable

        No classification

    • Multicore Circular Speaker Cable

        No classification

    • Parallel Speaker Cable

        No classification

    • Media Composite Cable

        No classification

    • Coax Jumper Cable/F Type Cable

        No classification

    • Audio Speaker Cable

        No classification

    • Audio XLR Cable

        No classification

    • HDMI
      • HDMI Cable

          No classification

      • HDMI Extender

          No classification

    • DisplayPort Cable

        No classification

    • DVI Cable

        No classification

    • VGA Cable

        No classification

    • Adaptors

        No classification

  • Universal Serial Bus
    • USB C Cable

        No classification

    • USB Hubs

        No classification

  • Control Cable
    • Fieldbus Cable

        No classification

    • Industrial Ethernet Cable

        No classification

    • PROFINET Cable

        No classification

    • Marine LAN Cable

        No classification

    • Flexible Control Cable

        No classification

    • Chain Cable

        No classification

    • SERVO Motor Cables

        No classification

    • Robotics Cables

        No classification

  • Power & Control Cable
    • Solar Cable
      • H1Z2Z2-1 Single

          No classification

      • H1Z2Z2-1 Twin

          No classification

      • UL4703

          No classification

      • TUV 2 pfG 2642/01.22

          No classification

      • Material

          No classification

      • Solar Connectors

          No classification

    • Battery Cable

        No classification

    • General Power Cable

        No classification

    • KNX Cable

        No classification

    • LV Armoured Cable SWA & AWA

        No classification

    • Automotive cable
      • American Standard
        • American Standard Battery Wire

            No classification

        • American Standard Primary Wire

            No classification

        • American Standard-More Type Wire

            No classification

      • Germany Standard

          No classification

      • Japanese Standard

          No classification

    • High Temperature Cable
      • Silicone 180℃ cable

          No classification

      • Silicone 200℃ cable

          No classification

      • Silicone 450℃ cable

          No classification

    • Flex Control Cable
      • LIYY Series Control Cables

          No classification

      • LiYCY Series Control Cables

          No classification

      • Unshielded Control Cables

          No classification

      • Shielded Control Cables

          No classification

      • Steel Wire Braid Control Cables

          No classification

    • Sensor & Actuator Cables

        No classification

    • RS485/232 Cable

        No classification

    • Hook Up wire

        No classification

  • other
    • Cable Materials
      • CCA WIRE

          No classification

      • CCAM WIRE

          No classification

      • Aluminum Foil

          No classification

      • Al-Mg alloy wire

          No classification

      • CCS WIRE

          No classification

      • Enameled aluminum wire(EAL)

          No classification

      • Enameled copper clad aluminum wire (ECCA)

          No classification

      • Enameled copper wire(EC)

          No classification

      • TCCA WIRE

          No classification

      • TCCAM WIRE

          No classification

      • Galvanized Steel Wire

          No classification

      • Stranded Wire

          No classification

  • Cabling Accessories
    • Feeder Cable Clamp

        No classification

Please select

    Please select superior classification

Please select

    Please select superior classification

Please select

    Please select superior classification

Please select

    Please select superior classification

Fiber Optic Cables

Indoor Fiber Optic Cables for Building, Distribution and Fire-Resistant Networks

ZION indoor fiber optic cables cover tight-buffered, duplex, multi-core, breakout, MPO, FTTX drop and fire-resistant constructions for controlled indoor routes and safety-driven infrastructure. Start with the installation environment, then choose fiber count, cable profile, strength member, jacket and fire-performance requirement before comparing individual models.

Which Indoor Fiber Optic Cable Products Are Available?

The range includes 21 product pages. Four broad series provide quick entry points, while the individual GJ and GY models narrow the choice by buffer structure, cable profile, strength member, armor and fire-performance construction.

Indoor 900 micrometer tight-buffered simplex and duplex fiber cables

TIGHT-BUFFERED SERIES

Indoor Tight-Buffered Optical Cables

A series covering 900 μm tight-buffered fiber plus simplex and duplex indoor cable types. Start here for patch cords, pigtails, equipment links and short indoor runs; confirm fiber grade, jacket and finished diameter.

View Product Details →
Indoor multi-fiber optical distribution cable range

DISTRIBUTION SERIES

Indoor Multi-Fiber Distribution Cables

Covers tight-buffered, mini, breakout and ribbon structures for organized multi-fiber routing. Consider it for indoor backbones, equipment areas and pre-terminated systems; confirm core count and termination plan.

View Product Details →
FTTX bow-type armored aerial and RRU drop cable range

FTTX DROP SERIES

FTTX Drop Cables

Includes bow-type, armored, aerial, duct and RRU-oriented options. Select by indoor or outdoor route, messenger or armor need, and installation method rather than treating every drop cable as interchangeable.

View Product Details →
G.657.A1 and G.657.A2 indoor fiber cable for MPO patch cords

MPO CABLE SERIES

G.657.A1/A2 Indoor Cable for MPO Patch Cords

A bend-insensitive indoor cable range for MPO–MPO trunks, MPO fan-outs and compact high-density patching. Confirm fiber count, polarity, connector gender, fiber grade and jacket before ordering.

View Product Details →
GJJV indoor 0.9 mm tight-buffer fiber optic cable

GJJV

0.9 mm Tight-Buffer Indoor Cable

A named 0.9 mm tight-buffer indoor construction for compact termination work. Consider it for pigtail or short indoor assembly designs and confirm fiber type, jacket and required finished construction.

View Product Details →
GYFZY all-dielectric fire-resistant stranded loose-tube optical cable

GYFZY

All-Dielectric Fire-Resistant Loose-Tube Cable

A stranded loose-tube fire-resistant construction identified as all-dielectric. Use it only where its tested fire performance and non-metallic design match the project specification.

View Product Details →
GYTZA53 flame-retardant double-armored loose-tube optical cable

GYTZA53

Double-Armored Flame-Retardant Cable

A stranded loose-tube cable with flame-retardant and double-armored construction. Consider it where mechanical protection is required together with a specified flame-performance level.

View Product Details →
GYZS53 plus 33 multi-armored fire-resistant optical cable

GYZS53+33

Multi-Armored Fire-Resistant Cable

A multi-armored fire-resistant construction for demanding mechanical routes. Confirm the exact armor layers, installation environment and required fire test before comparing it with lighter indoor models.

View Product Details →
GY F ZS53 fire-resistant stranded loose-tube optical cable

GY(F)ZS53

Fire-Resistant Stranded Loose-Tube Cable

A fire-resistant stranded loose-tube model listed with an all-dielectric description. Request the construction drawing to confirm the selected variant's material and protection layers.

View Product Details →
GYTZA flame-retardant stranded loose-tube optical cable

GYTZA

Flame-Retardant Stranded Loose-Tube Cable

A flame-retardant stranded loose-tube option without the double-armored designation. Use the project fire and mechanical requirements to decide whether this or a reinforced model is appropriate.

View Product Details →
GYFZA04 plus 33 anti-rodent anti-termite fire-resistant cable

GYFZA04+33

Multi-Armored Anti-Rodent and Anti-Termite Cable

Combines fire-resistant, multi-armored, anti-rodent and anti-termite design features. Consider it for severe routes only after confirming biological risk, armor requirement and project fire criteria.

View Product Details →
GYZS semi-dry fire-resistant steel-tape armored optical cable

GYZS

Semi-Dry Steel-Tape Armored Fire-Resistant Cable

A semi-dry cable with steel-tape armor and a fire-resistant construction. Select it when both water-management structure and mechanical protection are specified, then verify the required fire test.

View Product Details →
GJPFWQH indoor micro-tube breakout cable with FRP strength

GJPFWQH

Micro-Tube Breakout Cable with FRP Strength

An indoor micro-tube breakout construction with FRP strength. Consider it when a non-metallic strength approach and organized breakout routing are part of the cable specification.

View Product Details →
GJPFXJH breakout tight-buffer cable with FRP strength

GJPFXJH

Breakout Tight-Buffer Cable with FRP Strength

Combines tight-buffered breakout fibers with FRP strength. Choose it when direct branch handling and a non-metallic strength design are more important than the smallest possible cable profile.

View Product Details →
GJPFH indoor micro-tube breakout cable with CSM

GJPFH

Micro-Tube Breakout Cable with CSM

An indoor micro-tube breakout model using a CSM-based construction. Compare it with the FRP-strength version by route, pulling method and the selected model's construction drawing.

View Product Details →
GJBFJVH large-fiber-count mixed branch cable with CSM

GJBFJVH

Large-Fiber-Count Mixed Branch Cable

A mixed branch construction for larger fiber counts with CSM. Use it when a planned branch map must be built into the cable, and provide the complete core and breakout schedule with the RFQ.

View Product Details →
GJBFJV-II indoor multi-core branch fiber optic cable

GJBFJV-II

Indoor Multi-Core Branch Cable

A Type II multi-core branch cable for organized indoor distribution. Confirm the required branch lengths, core count, subunit identification and termination method before quotation.

View Product Details →
GJBFJV-I indoor multi-core branch cable with CSM

GJBFJV-I

Multi-Core Branch Cable with CSM

A Type I indoor multi-core branch cable using a CSM-based construction. Compare Type I and Type II only after confirming the branch plan and mechanical structure required by the project.

View Product Details →
GJPFJV multi-core tight-buffer bundle cable with aramid yarn

GJPFJV

Multi-Core Tight-Buffer Bundle Cable

A multi-core tight-buffer bundle reinforced with aramid yarns. Consider it for compact grouped indoor distribution and confirm fiber count, bundle identification and jacket requirements.

View Product Details →
GJFJBV flat duplex tight-buffer cable with aramid yarn

GJFJBV

Flat Duplex Tight-Buffer Cable

A flat duplex tight-buffer construction with aramid yarns. Choose the flat profile where route geometry or separation is important; confirm finished dimensions and connectorization.

View Product Details →
GJFJH duplex tight-buffer cable with aramid yarn

GJFJH

Round Duplex Tight-Buffer Cable

A duplex tight-buffer construction reinforced with aramid yarns. Choose it for a conventional round duplex route and compare finished diameter and handling requirements with the flat GJFJBV model.

View Product Details →

How Do I Choose the Right Indoor Fiber Cable?

Choose the installation condition before the model code. A short equipment link, a duplex pathway, a multi-core branch system and a safety-critical armored route require different structures even when they carry the same fiber type.

Patching or fixed distribution?

Use 900 μm tight-buffered or compact simplex/duplex constructions for pigtails, patch cords and short equipment links. Use multi-fiber distribution, breakout or branch cables when fibers must be grouped, routed and terminated across a building.

Round or flat duplex?

GJFJH is the round duplex option and GJFJBV is the flat duplex option. Select by pathway geometry, fastening method, separation need and connector assembly—not by appearance alone.

How many fibers and branches?

Define the total fiber count, subunit size, branch locations and termination type first. GJPFJV suits grouped tight-buffer bundles, while GJBFJV-I, GJBFJV-II and GJBFJVH address planned branch structures.

Need MPO or compact routing?

Use the G.657.A1/A2 MPO cable series when the assembly design requires bend-insensitive single-mode fiber and multi-fiber connectors. Fiber count, polarity, gender, key orientation, connector type and jacket rating still require confirmation.

Flame-retardant or fire-resistant?

Do not treat these terms as interchangeable. Match the cable to the project's named test standard, duration, circuit-continuity requirement, armor level and installation method, then request the selected model's supporting test documentation.

Quick Comparison

Use this table to select a structural family, then open the corresponding product card for the model-level page. Final fiber count, material, dimensions and test requirements should be confirmed for the selected version.

Product / ModelsVerified StructureSelection UseConfirm in RFQ
Tight-Buffered Series / GJJV900 μm tight buffer; simplex and duplex rangePigtails, patching, short indoor linksFiber grade, jacket, diameter, termination
GJFJH / GJFJBVRound or flat duplex tight-buffer; aramid yarnsTwo-fiber indoor linksProfile, dimensions, connector assembly
GJPFJVMulti-core tight-buffer bundle; aramid yarnsGrouped indoor distributionCore count, identification, jacket
GJPFWQH / GJPFXJH / GJPFHMicro-tube or tight-buffer breakout; FRP or CSMBreakout routing and direct branch handlingStrength design, pulling load, subunits
GJBFJV-I / GJBFJV-II / GJBFJVHMulti-core or mixed branch; CSM variantsPreplanned indoor branch networksBranch map, lengths, core schedule
MPO Cable SeriesG.657.A1/A2 indoor cable; MPO trunk and fan-out optionsHigh-density pre-terminated cablingCount, polarity, gender, jacket
FTTX Drop SeriesBow-type, armored, aerial, duct and RRU optionsSubscriber drops and application-specific routesEnvironment, messenger, armor, fibers
GYFZY / GYTZA / GY(F)ZS53Loose-tube fire-resistant or flame-retardant constructionsSafety-driven infrastructureExact test standard and material layers
GYTZA53 / GYZS53+33 / GYFZA04+33 / GYZSArmored, multi-armored or steel-tape fire-performance constructionsRoutes needing added mechanical protectionArmor, fire test, route and biological risk

Where Are Indoor Fiber Optic Cables Used?

These cables fit controlled building routes, structured distribution and specified safety-critical infrastructure. A model is suitable only when its mechanical, fire, jacket and termination requirements match the actual pathway.

Equipment rooms and patching

Tight-buffered simplex or duplex cables support short equipment, panel and pigtail assemblies. Confirm connector type, fiber grade, jacket and bend control for the finished assembly.

Building distribution

Multi-core bundle, breakout and branch cables organize fibers between telecom rooms, zones and equipment areas. They are not automatically suitable for unprotected outdoor exposure.

Data centers and MPO systems

MPO-oriented indoor cable constructions support dense pathways and pre-terminated links. The cable alone does not define polarity, connector gender or channel performance.

FTTx access routes

Bow-type and related FTTX drop structures connect distribution points to subscriber or application endpoints. Select indoor, aerial, duct, armored or RRU versions by the actual route.

Transit and safety-critical routes

Fire-performance and armored models may fit tunnels, stations and protected infrastructure when the selected cable is tested to the standard named by the project. Do not substitute a generic flame-retardant cable for a required fire-resistant design.

Frequently Asked Questions

What is an indoor fiber optic cable?

It is a fiber cable constructed for building interiors, equipment spaces or other controlled routes. The main buying decisions are buffer style, fiber count, profile, strength member, jacket, termination and fire-performance requirement.

When should I choose tight-buffered cable?

Choose it when easy fiber handling and direct termination are priorities, such as pigtails, patch cords and short indoor equipment links. For larger building backbones, compare multi-fiber distribution or breakout structures.

What is the difference between GJFJH and GJFJBV?

Both are duplex tight-buffer models with aramid yarns, but GJFJH is the round-profile option and GJFJBV is the flat-profile option. Confirm dimensions and route geometry before choosing.

Can indoor fiber cable be installed outdoors?

Only when the selected construction is rated for that route. Standard indoor cables should not be assumed to withstand UV, moisture, aerial loading, burial or other outdoor exposure; use the appropriate FTTX or outdoor-rated version.

Is flame-retardant cable the same as fire-resistant cable?

No. Flame retardance limits flame spread under a specified test, while a fire-resistant design may be required to maintain circuit function for a defined condition and duration. Match the exact project standard and evidence.

What information is needed for a custom branch or MPO cable?

Provide the fiber count and grade, branch map or MPO polarity, connector details, lengths, jacket requirement, pathway conditions, labeling and test criteria. These details determine the finished assembly more reliably than a family name alone.

RFQ Checklist

Provide the items below so the cable family, detailed construction and test requirements can be checked before quotation.

  • Installation environment: equipment room, riser, tray, tunnel, duct, aerial route or other pathway

  • Fiber type, fiber count and color-identification requirement

  • Cable structure: simplex, duplex, tight-buffer bundle, breakout, branch, ribbon, MPO or FTTX drop

  • Strength member and armor requirement, including metallic or all-dielectric preference

  • Jacket material, color, finished diameter and installation length

  • Flame-retardant or fire-resistant test standard and required performance level

  • For branch cables: branch positions, subunit lengths, core map and termination method

  • For MPO assemblies: polarity, gender, key orientation, connector type and end-face requirement

  • Quantity, packaging, labeling, inspection and test-report requirements

CONTACT US
Professional OEM - Zion Communication
picture1

Request a Quote​​​​​​​
Contact Us